The use of two large blowers and two small blowers, sequenced properly, provided 100 percent back-up and a wide range of control to meet varying demand loads.

low-pressure-blowers

The ambient air, gravity-fed system needed a boost from the low-pressure blowers as demand for propane gas increased from residential and commercial expansion.

pressure-flow-controller-package

A pressure and flow controller package, engineered and installed by Sorensen Systems, integrates the existing digital controls for the four blower units.




 

NH Gas Propane Distribution System
Gets Unique Blower Control Package

Conversion from Gravity to Pressurized System

The New Hampshire Gas Company, headquartered in Keene, NH, is the only community in the country with a municipal propane gas distribution system. While many communities have natural gas systems, no one else has a propane gas system for an entire community. According to David Jacques, Assistant General Manager and David Grande, Manager of Operations for NH Gas, the existing distribution system, which essentially uses ambient air, was determined to be inadequate for dealing with the increasing demand for commercial propane customers in the town.

Custom Blower System

The challenge was how to move from a gravity-fed system to a pressurized system to meet the increasing demand. NH Gas relied on engineering design and system fabrication from Sorensen Systems to identify and construct a solution. The custom blower system engineered by the team at Sorensen Systems was designed to provide a stabilized pressure source for the propane gas distribution throughout the Keene, NH community. NH Gas is a subsidiary of Berkshire Gas Company, based in Pittsfield, MA.

Flow Controller Package

Sorensen Systems engineers developed a system utilizing four rotary-lobe blowers, which were linked together to provide the required controlled pressure and internal back-up and redundancy capability. A pressure and flow controller package integrates the existing digital controls for the system. A new pressure sensor was mounted on the existing line, which mixes the propane, to provide the correct ratios and proportioning to meet varying demands.

Developed Software Programming

Sorensen Systems engineers developed the software programming that permits the four blowers to operate in sequence to meet various load levels and to serve as internal back-ups during maintenance shutdowns. The challenge was to integrate the new blower system with the non-automated pre-existing system, which relied on a series of solenoids actuated by a binary timer package.

Replaced Multiple Venturis

According to David Jacques, of NH Gas, the current system used multiple venturis to provide air to mix with the propane for the correct BTU ratio. Going forward, the requirement was to provide air over a broad 50 cfm to 1,400 cfm range, with enough available capacity to maintain pressure, even if one of the blower units failed. Through a unique manifold package designed at Sorensen Systems, the four blowers were linked together with sensors to regulate the air requirements.

Centralized, Underground Distribution

According to one of the sales engineers at Sorensen Systems, the propane pipeline system provided by NH Gas is highly unusual. "Keene is the only city in the country that has a centralized, underground propane distribution network to provide gas at a required pressure and ratio to an entire community. The system is not automated. It is operated through an ingenious system utilizing digital monitors and recorders to monitor gas ratios and controls," said the sales engineer.

Sequenced Package of Blowers

The original inquiry from NH Gas was based on a requirement for air compressors to supply a solution to their problem. Upon evaluation by Sorensen Systems engineers it was agreed that a more efficient, reliable and cost-effective solution would be derived from a sequenced package of blowers.

Large volume, Low pressure air

The need for large volume, low pressure air, instead of high pressure air from a compressor, was the deciding factor. The final design included two 50 horsepower units and two 10 horsepower units, which provided the range of pressure required regardless of hot summer months or freezing winter. The units were selected for reliability and compact design. Floor space was at a premium and routine maintenance and operational requirements were factored into the selection of equipment.


^top

 

               
               


Sorensen Systems

A Subsidiary of THG Corporation
70 Bearfoot Road
Northborough, MA 01532

T: 508-393-7660
F: 508-393-6042

REQUEST INFORMATION


 
 
  FEATURE STORY
  Who Knew that Pink
Meant Hydraulics?

When the specification said the machine was to be painted pink, who knew there was more than one pink? Pink Hydraulic Power Units

 
  TECHNICAL SUPPORT
  Read Mike's Best
Online Tool Links

Our VP of Engineering has some
favorite online conversion tools
that you may find useful.
Mike's Conversion Tools
 
  SORENSEN BLOG
  Our Engineers Comment
On Topics of Interest

Each month our engineers take up a topic and add their insight. It can range from motion control to electricity cost. Sorensen Blog.
   
       
  Sorensen Engineered Systems
Division of Sorensen Systems


70 Bearfoot Road
Northborough, MA 01532

  Phone: 508-393-7660
Fax: 508-393-8203
Email • Terms & Conditions • Disclaimer • Jobs • Our Mission
© 2018, Sorensen Systems. All rights reserved